What was found
DURING C-CHECK, FOUND RIGHT AFT STAIRWELL AREA, VERTICAL WEB OF LOWER TORQUE BOX CRACKED APPROX .75 INCH FROM OUTBOARD TO INBOARD AT STATION 1263. INSTALLED TYPICAL WEB REPAIR AS PER SRM 51-40-2 AT VERTICAL WEB OF LOWER TORQUE BOX STATION 1263. MATERIAL 7075-T6 .063 3 INCH BY 6 INCH.