What was found
DURING C-CHECK, HFEC HAS INDICATED CRACKS ONE EACH STATION 870 JUST BELOW STRINGER 9R MAIN FRAME SPLICE OUTBOARD FLANGE, CRACKS LOCATED NEXT TO AFT ROW, ROW 3 NEXT TO BOTTOM HOLE (THIRD HOLE FROM TOP) AT ABOUT 11 O'CLOCK POSITION. REAMED HOLE TO NEXT SIZE .0156 AS PER SRM 51-30-2. PARTIAL REPLACEMENT OF TERMINAL FITTING STRINGER 9 TO STRINGER 12 RIGHT SIDE BS 870 AS PER SB 727-53-0194. COMPLIED WITH SB PER ECD 92-727-5311-006.