As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHECK, HFEC CRACK INDICATION AT NR 2 CARGO DOOR CUT OUT FWD FRAME WEB, JUST INBOARD OF LOWER FRAME DOOR STOP IN LINE WITH STRINGER 26R CRACK AND END OF CRACK. STOP DRILLED CRACK PER 51-10-1. INSTALLED WEB REPAIR PER SB 727-53-199R1 P 93110229 .080 7075-T6 LOT 670971 12 INCH BY 3.5 INCH AT NR 2 CARGO DOOR CUT OUT FWD LWR CORNER.