What was found
DURING C-CHECK, CORROSION ON FWD FACE AT STATION 1148, STRINGER 27L. CUT OUT DAMAGED AREA PER SRM 51-40-3. FABRICATED FILLER 7075-T6 .091 1 INCH BY 2.5 INCH DOUBLER 7075-T6 .063 6 INCH BY 18 INCH, INSTALLED AS PER SRM 51-40-3. ALODINED AND PRIMED PER SRM 51-10-6.