What was found
DURING D-CHECK, FIXED WING LEADING EDGE STATION 130.7 INNER RIB HAS LOWER INBD INNER REPAIR ANGLE CRACKED 5 INCHES FROM FWD END. REMOVED FASTENERS FROM REPAIR ANGLE. REMOVED FASTENERS FROM ANGLE AND CUT OUT ANGLE PER SRM 51-40-4. FABRICATED ANGLE 2024-T3 .063 1 INCH BY 1 INCH BY 24 INCH, ALODINED AND PRIMED PER SRM 51-10-2. FABRICATED SPLICE ANGLE PER SRM 51-40-3 5 INCH BY 2 INCH ALODINED AND PRIMED PER SRM 51-10-2. INSTALLED NEW ANGLE AND SPLICE ANGLE PER SRM 51-10-1. INSTALLED NUT PLATES PER SRM 51-10-1.