What was found
DURING D-CHECK, FOUND MAIN CABIN STATION 1180 RBL 28, DITCHING PLATE IS CRACKED. FABRICATED NEW DITCHING PLATE PER SRM 51-10-1. ALODINED AND PRIMED PER SRM 51-10-2. INSTALLED DOUBLER 2024-T3 .025 6 INCH BY 3 INCH PER SRM 51-10-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, FOUND MAIN CABIN STATION 1180 RBL 28, DITCHING PLATE IS CRACKED. FABRICATED NEW DITCHING PLATE PER SRM 51-10-1. ALODINED AND PRIMED PER SRM 51-10-2. INSTALLED DOUBLER 2024-T3 .025 6 INCH BY 3 INCH PER SRM 51-10-1.