What was found
DURING D-CHECK, STATION 1183 TO 1203 BETWEEN STRINGER 25R AND 24R, HAS DENT FILLED WITH BONDO AND HAS A GOUGE JUST AFT OF 1183 BUTT SEAM. REMOVED FILLER MATERIAL PER SRM 51-40-1. FOUND DENT TO BE BEYOND LIMITS PER SRM 53-30-1. CUT OUT DAMAGED AREA AS PER SRM 53-30-3. FABRICATED DOUBLER .080 2024-T3 20 INCH BY 11 INCH PER SRM 53-30-3. INSTALLED DOUBLER PER SRM 53-30-3.