What was found
DURING D-CHECK, MAIN CABIN STATION 1180 LBL 27, DITCHING PLATE CRACKED. STOP DRILLED AT THE END OF CRACK PER SRM 51-10-1. FABRICATED DOUBLER 2024-T3 .025 6 INCH BY 4 INCH. INSTALLED DOUBLER REPAIR AS PER SRM 51-40-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, MAIN CABIN STATION 1180 LBL 27, DITCHING PLATE CRACKED. STOP DRILLED AT THE END OF CRACK PER SRM 51-10-1. FABRICATED DOUBLER 2024-T3 .025 6 INCH BY 4 INCH. INSTALLED DOUBLER REPAIR AS PER SRM 51-40-2.