DURING D-CHECK, MAIN CABIN FLOOR SUPPORT ANGLE IS CORRODED AT STATION 745 LBL 65 INCHES. REMOVED FLOOR SUPPORT ANGLE PER SRM 51-30-2. INSTALLED NEW FLOOR ANGLE SUPPORT PER SRM 51-10-1 PAGE 4 AND SRM 51-30-2, SIZE 107 INCHES BY 1.5 INCH BY 1.25 INCH BAC 1515-532 T-6 .071 INCH.