What was found
CLT - INSPECTION BY ULTRASONIC, FOUND TWO AREAS OF DISBOND, 14 INCHES BY 8 INCHES AND 4 INCHES BY 8 INCHES LOCATED AT THE FUSELAGE SKIN AT STATION 312-344 AND STRINGER 5R AND STRINGER 6R. INSTALLED FIELD FASTENERS AS PER BOEING SRM 53-30-3 FIG 17, DETAILS I AND II. (M)