What was found
CLT - INSPECTION VISUALLY FOUND LEVEL I CORROSION AT THE FUSELAGE FLOOR SUPPORT BEAM LOCATED AT LBL 2 TO LBL 6 AND STATION 1014. FABRICATED REPLACEMENT H-CHANNEL AND ATTACH ANGLE AS PER BOEING SRM 51-00-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - INSPECTION VISUALLY FOUND LEVEL I CORROSION AT THE FUSELAGE FLOOR SUPPORT BEAM LOCATED AT LBL 2 TO LBL 6 AND STATION 1014. FABRICATED REPLACEMENT H-CHANNEL AND ATTACH ANGLE AS PER BOEING SRM 51-00-02. (M)