What was found
CLT - INSPECTION BY ULTRASONIC, FOUND SKIN AND DOUBLER DISBOND LOCATED AT FUSELAGE SKIN MEASURING 14 INCHES BY 2.5 INCHES AT STATION 902 TO 914 AND STRINGER 13R TO STRINGER 14R. INSTALLED FIELD RIVETS AS PER BOEING SRM 53-30-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - INSPECTION BY ULTRASONIC, FOUND SKIN AND DOUBLER DISBOND LOCATED AT FUSELAGE SKIN MEASURING 14 INCHES BY 2.5 INCHES AT STATION 902 TO 914 AND STRINGER 13R TO STRINGER 14R. INSTALLED FIELD RIVETS AS PER BOEING SRM 53-30-3. (M)