What was found
CLT - INSPECTION BY ULTRASONIC, FOUND SKIN AND DOUBLER DISBOND LOCATED AT FUSELAGE SKIN MEASURING 3 INCHES BY 4 INCHES AT STATION 967 ABOVE STRINGER 5L. INSTALLED FIELD RIVETS AS PER SRM 53-30-3 FIG 17. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - INSPECTION BY ULTRASONIC, FOUND SKIN AND DOUBLER DISBOND LOCATED AT FUSELAGE SKIN MEASURING 3 INCHES BY 4 INCHES AT STATION 967 ABOVE STRINGER 5L. INSTALLED FIELD RIVETS AS PER SRM 53-30-3 FIG 17. (M)