What was found
CLT - INSPECTION BY ULTRASONIC, FOUND SKIN AND DOUBLER DISBOND MEASURING 12 INCHES BY 2.5 INCHES LOCATED FUSELAGE SKIN AT STATION 927-947 AND STRINGER 14L. INSTALLED FIELD FASTENERS AS PER SRM 53-30-3 FIG 17 DETAIL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - INSPECTION BY ULTRASONIC, FOUND SKIN AND DOUBLER DISBOND MEASURING 12 INCHES BY 2.5 INCHES LOCATED FUSELAGE SKIN AT STATION 927-947 AND STRINGER 14L. INSTALLED FIELD FASTENERS AS PER SRM 53-30-3 FIG 17 DETAIL 1. (M)