What was found
FOUND BS 481 SKIN THICKNESS LOSS 10 PERCENT AT MANY STRINGER STATIONS IN BETWEEN STRINGER 10L AND STRINGER 10R, CROWN AREA INSPECTED PER AD 90-26-09. REMOVED AND REPLACED FASTENERS WITH OVERSIZE FASTENERS FROM STRINGER 2L TO 10L AND FROM STRINGER 7R TO 10R PER SB 727-53-0084. SKIN REPAIRED FROM STRINGER 2L TO 4R ON NR 19N00043 AND FROM STRINGER 4R TO 7R ON NR 19N00039.