What was found
DURING D-CHECK, CORROSION ON SUB-FLOOR, STA 1160, BLL 23. CUT 10 INCH BY 7 INCH CORRODED AREA AND INSTALLED 12 INCH BY 10 INCH .063 INCH 7075-T6 DOUBLER PER SRM 51-40-2. TAT: 53,881.4. TAC: 36,380.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, CORROSION ON SUB-FLOOR, STA 1160, BLL 23. CUT 10 INCH BY 7 INCH CORRODED AREA AND INSTALLED 12 INCH BY 10 INCH .063 INCH 7075-T6 DOUBLER PER SRM 51-40-2. TAT: 53,881.4. TAC: 36,380.