What was found
DURING D-CHECK, FUEL VENT LINE AT WS 629 AND WS 601, CHECK THAT REPAIR IS IN C/W E.O. REPAIR. BLENDED OUT PER SRM 51-40-1. MATERIAL LOOSE .002 INCH. INSTALLED REPAIR PER AVITAS ENGINEERING NR 95PMSI.049RO-0 IN BOTH LOCATIONS. TAT: 53,881.4 HRS. TAC: 36,380.