What was found
DURING D-CHECK, STA 920, LT VERTICAL SUPPORT AT STR 15 IS CRACKED AT FASTENER LOCATION. STOP-DRILLED CRACK PER SRM 51-10-01. FABRICATED DOUBLER PER SRM 51-40-3. INSTALLED DOUBLER PER SRM 51-40-21, 5 INCH BY 2 INCH, 2024T3.071. TAT: 53,881.4 HRS. TAC: 36,380.