What was found
ACTUATOR WAS SHIPPED AS A SERVICEABLE UNIT. TEST PER SIL 1125-27-082 R2. ACTUATED WORM GEAR DRIVE TO MIX THE PC-10 GREASE, FULL TRAVEL BOTH DIRECTIONS. FROZE TO MINUS 50 DEGREES FAHRENHEIT, MINUS 60 DEGREES FAHRENHEIT FOR 1.5 HRS. BRAKE AWAY TORQUE OF 18 INCH/POUNDS OK. RUN TORQUE 12 INCH/POUNDS WAS VERY CLOSE. EEMCO SAYS THAT ACTUATOR PASSES THEIR TEST TO MINUS 65 DEGREES FAHRENHEIT. ACTUATOR WAS INSTALLED PER ASTRA JET CORP. SUBMITTER RECOMMENDS BETTER FIELD TESTING INSTRUCTIONS.