As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ACTUATOR WAS SHIPPED AS A SERVICEABLE UNIT. TEST PER SIL 1125-27-082 R2 ACTUATED WORM GEAR DRIVE TO MIX PC-10. FULL TRAVEL, BOTH DIRECTIONS. FROZE TO MINUS 50 DEGREES FAHRENHEIT, MINUS 60 DEGREES FAHRENHEIT FOR 1.5 HRS. BRAKE AWAY TORQUE OF 18 INCH/POUNDS OK. RUN TEST OF 12 INCH/POUNDS WOULD NOT PASS. UNIT WAS TESTED AND REPAIRED AND SHIPPED H6-96.