What was found
DURING D-CHECK, LOWER AFT CARGO BENT FRAME STA 950 AT STR 26L. FABRICATED AND INSTALLED FRAME REPAIR PER SRM 53-10-4 AND SRM 51-30-2, 10 INCHES BY 3.5 INCHES, 7075-T6 .071 INCH. TAT: 45,788.3 HRS. TAC: 29,959.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, LOWER AFT CARGO BENT FRAME STA 950 AT STR 26L. FABRICATED AND INSTALLED FRAME REPAIR PER SRM 53-10-4 AND SRM 51-30-2, 10 INCHES BY 3.5 INCHES, 7075-T6 .071 INCH. TAT: 45,788.3 HRS. TAC: 29,959.