What was found
FOUND CYLINDER COMPRESSION AT 40/80. REMOVED CYLINDER AND FOUND EXHAUST VALVE GUIDE WORN OVER LIMITS. EXHAUST VALVE IN GUIDE CLEARANCE AS MEASURED IS 0.016 INCH. SERVICEABLE LIMITS ARE 0.006 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CYLINDER COMPRESSION AT 40/80. REMOVED CYLINDER AND FOUND EXHAUST VALVE GUIDE WORN OVER LIMITS. EXHAUST VALVE IN GUIDE CLEARANCE AS MEASURED IS 0.016 INCH. SERVICEABLE LIMITS ARE 0.006 INCH.