What was found
BATHTUB FITTING HAS LEVEL 2 CORROSION, FS 270, L25. REMOVED FITTING, REMOVED CORROSION, REINSTALLED FITTING IAW SRM'S 51-1-3, 51-1-8, 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BATHTUB FITTING HAS LEVEL 2 CORROSION, FS 270, L25. REMOVED FITTING, REMOVED CORROSION, REINSTALLED FITTING IAW SRM'S 51-1-3, 51-1-8, 51-1-20D.