What was found
DISASSEMBLY AFTER ALTERNATOR FAILURE REVEALED PREMATURE AND EXCESSIVE WEAR ON BRUSHES. TIME SINCE OVERHAUL 141.0 HOURS. SUBMITTER STATED POSSIBLE DEFECTIVE BRUSHES OR IMPROPER INSTALLATION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DISASSEMBLY AFTER ALTERNATOR FAILURE REVEALED PREMATURE AND EXCESSIVE WEAR ON BRUSHES. TIME SINCE OVERHAUL 141.0 HOURS. SUBMITTER STATED POSSIBLE DEFECTIVE BRUSHES OR IMPROPER INSTALLATION.