What was found
FUSELAGE STATION 680 BETWEEN RIGHT STR 15 AND STR 16, THERE IS A 5 INCH CRACK IN THE FRAME SHEAR TIE THROUGH ATTACH FASTENER. FABRICATED AND INSTALLED REPAIR SHEAR TIE PER SRM 53-10-4 AND SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE STATION 680 BETWEEN RIGHT STR 15 AND STR 16, THERE IS A 5 INCH CRACK IN THE FRAME SHEAR TIE THROUGH ATTACH FASTENER. FABRICATED AND INSTALLED REPAIR SHEAR TIE PER SRM 53-10-4 AND SRM 51-30-2.