What was found
DURING WINDSHIELD REPLACEMENT, FOUND AILERON CONTROL CABLE, WHICH TRAVELS UP THE FORWARD RIGHT DOOR POST, WAS CHAFING ON THE ADJACENT FUEL LINE. ORIGINAL WALL THICKNESS IS .030 INCH AND THE DEPTH OF THE CHAFE WAS .020 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING WINDSHIELD REPLACEMENT, FOUND AILERON CONTROL CABLE, WHICH TRAVELS UP THE FORWARD RIGHT DOOR POST, WAS CHAFING ON THE ADJACENT FUEL LINE. ORIGINAL WALL THICKNESS IS .030 INCH AND THE DEPTH OF THE CHAFE WAS .020 INCH.