What was found
LEVEL 2 CORROSION, FLOOR SUPPORT CORRODED AT LBL 22 BETWEEN STA 1585 AND STA 1605. REMOVED DAMAGED SECTION OF FLOOR SUPPORT, FABRICATED AND INSTALLED REPAIR PER SRM 51-50-02. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION, FLOOR SUPPORT CORRODED AT LBL 22 BETWEEN STA 1585 AND STA 1605. REMOVED DAMAGED SECTION OF FLOOR SUPPORT, FABRICATED AND INSTALLED REPAIR PER SRM 51-50-02. (X)