What was found
PROPELLERS WERE IN FOR TIME OVERHAUL. THREE OF THE BLADE CLAMPS WERE REJECTED FOR CORROSION INSIDE THE CLAMP WHERE CONTACT IS MADE WITH THE BLADE THRUST BEARING. ONE CLAMP WAS REJECTED FOR A CRACK THAT RAN PARALLEL TO THE CLAMP HAD SPLIT. IT WAS ALSO FOUND THAT THE WRONG SPRING ASSY WAS INSTALLED IN BOTH PROPELLERS. THE WRONG SPRING ASSY HAS HIGHER SPRING TENSION THAN THE ONE THAT SHOULD HAVE BEEN INSTALLED. THE SPRING ASSYS WERE CHANGED AND THE FOUR CLAMP ASSYS WERE REPLACED ALONG WITH OVERHAUL OF THE PROPS AND RETURNED TO SERVICE.