SDR 96ZZZX5343

Service difficulty report · Filter · Blanca 1730

Difficulty date
October 11, 1996
Submitted
March 26, 2000
Operation
General aviation
Aircraft
N6667V
Make and model
Blanca 1730
Aircraft serial
30018
Part
Filter
Part number
EGB03003
Condition
Blocked Yoke
Location
Vacuum Inlet
Stage of operation
NR
Nature of condition
F
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FILTER PREVENTED YOKE FROM FORWARD MOVEMENT. WHEN FILTER WAS INSTALLED IT WAS NOT HARD MOUNTED. HOSES WERE HOLDING FILTER. HOSE CLAMP LOOSENED ALLOWING FILTER TO MOVE. HARD MOUNTED FILTER TO AIRCRAFT FRAME USING LOCKNUT AND ADEL CLAMP. REPLACED HOSES. SUBMITTER STATED NO LOCATION FOUND IN AIRCRAFT MANUALS FOR FILTER INSTALL.