SDR 96ZZZX6016

Service difficulty report · Torque Tube · Piper PA24250

Difficulty date
October 23, 1996
Submitted
March 26, 2000
Operation
General aviation
Aircraft
N6996P
Make and model
Piper PA24250
Aircraft serial
242139
Part
Torque Tube
Part number
2020302
Condition
Rusted
Location
Elev
Stage of operation
IN
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

REMOVED ELEV FROM STABILATOR TUBE FOR PAINTING AIRCRAFT. HAD TO REMOVE INSIDE BLOCK ASSY FIRST DUE TO ELEV WOULD NOT SLIDE OFF. ELEV WOULD NOT SLIDE OFF DUE TO RUST BUILD-UP ON STAB TUBE. SUSPECT CAUSE OF RUST BUILD-UP IS MOISTURE IN ELEV. SUBMITTER RECOMMENDS REMOVAL OF ELEV ONCE EVERY 2 YEARS FOR INSP AND CLEANING OF TUBES.