What was found
DURING A SCHEDULED INSPECTION AT AERO CORP, CORROSION WAS FOUND IN THE E/E COMPARTMENT FRAMES AT STA 130 AND STA 160 BETWEEN S28L TO S28R. REMOVED FRAME STA 130 AND SHEAR CLIP. CORROSION OUT OF LIMITS IAW DC9 SRM 53-01 FIG 1. FABBED NEW SHEAR CLIP IAW DC9 SRM 53-11-3, DIMENSIONS 53.5 INCHES BY 2.5 INCHES. MECHANICALLY REMOVED CORROSION FROM FRAME 130 AND FRAME 160, WITHIN LIMITS. SHEAR CLIP STA 160 OUT OF LIMITS IAW DC9 SRM 53-01 FIG 1. FABBED REPAIR IAW DC9 SRM 53-01 FIG 2. ALODINED AND PRIMED IAW DC9 SRM 51-10-3. INSTALLED FRAME AND SHEAR CLIP STA 130 AND STA 160 IAW DC9 SRM 51-30-2.