What was found
DURING A SCHEDULED INSPECTION AT AERO CORP, CORROSION WAS FOUND IN THE AFT CARGO PIT AT STA 756 S30 AROUND FASTENERS. REMOVED CORROSION, OUT OF LIMITS IAW DC9 SRM 53-01, WAS .180 INCH, NOW .130 INCH. NDT VERIFIED. REMOVED CORRODED END OF SPLICE IAW DC9 SRM 53-02 FIG 12. FABBED LONGERON 30 END SPLICE. INSTALLED LONGERON 30 END SPLICE, TORQUED BOLTS IAW DC9 SRM 51-30-2. INSTALLED END SPLICE IAW DC9 SRM 51-30-2 AND SRM 51-30-5.