What was found
DURING A SCHEDULED INSPECTION AT AERO CORP, CORROSION WAS FOUND IN THE AFT CARGO PIT, STA S30 FROM STA 897 TO STA 965. MECHANICALLY REMOVED CORROSION. CORROSION FOUND TO BE OUT OF LIMITS IAW DC9 SRM 51-01 FIG 1. REMOVED CORRODED AREA OF STR 30 IAW DC9 SRM 51-01. CLEANED BLUE WATER FROM STA 897 TO STA 963 IAW DC9 SRM. TREATED AND PRIMED LONGERON FROM STA 897 TO STA 963 IAW DC9 SRM 51-10-3. INSTALLED LONGERON AND SPLICES AT STA 897 TO STA 963 IAW DC9 SRM'S 51-30-0 51-30-1, 51-30-2, 51-30-5.