What was found
LEFT HORIZONTAL STABILIZER ATTACH FITTING ON STABILIZER SPAR FOUND CRACKED. INTERGRANULAR CORROSION EVIDENT ON THE COMPLETE LENGTH OF CRACK. PART IS HIGHLY LOADED AND SUBJECT TO STRESS CORROSION. SUBMITTER STATED THIS FITTING SHOULD BE EXAMINED CAREFULLY DURING THE REPETITIVE INSPECTIONS REQUIRED BY AD 92-24-02. THESE FITTINGS ARE REMOVED FOR THE INSPECTION OF SPAR.