What was found
DURING APPROACH ON GEAR EXTENSION, THE NOSE GEAR SAFE GREEN LIGHT DID NOT ILLUMINATE. PERFORMED COCKPIT OPERATING MANUAL PROCEDURE AND RECYCLED GEAR, ALL INDICATIONS WERE NORMAL. FLIGHT LANDED WITHOUT INCIDENT. MAINTENANCE ADJUSTED THE NOSE GEAR LOCK SWITCH. SWUNG GEAR SEVERAL TIMES, OPERATIONAL CHECK OK.