What was found
DURING APPROACH, THE RIGHT MAIN LANDING GEAR GREEN LIGHT FAILED TO ILLUMINATE AFTER GEAR EXTENSION. RECYCLED GEAR AND NORMAL INDICATIONS WERE ACHIEVED. MAINTENANCE WAS UNABLE TO DUPLICATE PROBLEM ON GROUND. REPLACED THE RIGHT MAIN GEAR DOWNLOCK SWITCH AS A PRECAUTION, OPERATIONAL CHECK NORMAL.