What was found
DURING LINE CHECK, FOUND THAT EXCESSIVE FORCE WAS REQUIRED TO PULL EXTERNAL TAIL CONE RELEASE HANDLE FROM RETAINING CLIPS. ALSO, FOUND BROKEN RETAINING CLIP ON INTERNAL RELEASE HANDLE. REPLACED INTERNAL RETAINING CLIP AND ADJUSTED EXTERNAL CLIPS, OPERATIONAL CHECK OK.