SDR 9707789884

Service difficulty report · Temp Sensor · Doug DC951

Difficulty date
April 16, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N677MC
Make and model
Doug DC951
Aircraft serial
47756
Part
Temp Sensor
Condition
Failed
Location
Right
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CLIMB-OUT OF DFW PASSING 17,000, TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. FOLLOWED COCKPIT OPERATING MANUAL PROCEDURE. LIGHT REMAINED ON. LIGHT EXTINGUISHED WHEN POWER RETARDED TO 1.5 EPR. FLIGHT RETURNED TO DFW AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED DUCTING FOR LEAKAGE AND FOUND NONE. REPLACED TEMPERATURE SENSOR ON RIGHT SIDE. OPERATIONAL CHECK OK.