What was found
DURING APPROACH, NOSE LANDING GEAR GREEN DOWNLOCK LIGHT DID NOT ILLUMINATE AFTER GEAR EXTENSION. CREW REPLACED INDICATION LIGHT BULBS AND RECYCLED GEAR. NORMAL INDICATIONS WERE ACHIEVED. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED BOTH NOSE GEAR GREEN INDICATION BULBS, OPERATIONAL CHECK NORMAL.