SDR 9717879610

Service difficulty report · Temp Controller · Doug DC932

Difficulty date
September 19, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N610NW
Make and model
Doug DC932
Aircraft serial
47432
Part
Temp Controller
Condition
Malfunctioned
Location
Right
Stage of operation
CL
Nature of condition
B, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF, FLIGHT ATTENDANTS REPORTED CABIN AS BEING VERY WARM WITH SMOKE PRESENT. ALARM IN RIGHT LAVATORY ACTIVATED. CREW TURNED OFF BOTH PACKS AND SMOKE BEGAN TO DISSIPATE. FLIGHT WAS RETURNED TO GRB AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED RIGHT TEMPERATURE CONTROLLER, RIGHT TEMPERATURE CONTROL VALVE AND RIGHT WATER SEPARATOR BAG AND OPERATIONAL CHECK NORMAL.