SDR 9718619965

Service difficulty report · Clamp · Doug DC931

Difficulty date
October 1, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N911RW
Make and model
Doug DC931
Aircraft serial
47179
Part
Clamp
Condition
Leaking
Location
Pneumatic Syst
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED AFTER TAKEOFF. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND AIR LEAK AT FORWARD CLAMP ON PNEUMATIC CROSSFEED VALVE. REPOSITIONED CLAMP. LEAK AND OPERATIONAL CHECK NORMAL. AIRCRAFT RETURNED TO SERVICE.