What was found
DURING LINE MAINTENANCE INSPECTION, FOUND FORWARD CABIN FLOOR PROXIMITY EMERGENCY LIGHTS INOPERATIVE. REPLACED FUSE IN EXIT SIGN AT GALLEY SERVICE DOOR, OPERATIONAL CHECK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING LINE MAINTENANCE INSPECTION, FOUND FORWARD CABIN FLOOR PROXIMITY EMERGENCY LIGHTS INOPERATIVE. REPLACED FUSE IN EXIT SIGN AT GALLEY SERVICE DOOR, OPERATIONAL CHECK NORMAL.