What was found
NR 0615 006. CORROSION (C53-221-01) AT STA 245 UNDER CAPTAIN'S NR 3 WINDOW, WL 227. REMOVED CORROSION 3 INCH BY 4 INCH BY .049 INCH FROM ORIGINAL THICKNESS OF .065 INCH. FOUND TO BE OUT OF LIMITS PER FED-EX SRM 53-10-1. REMOVED DAMAGED AREA AND INSTALLED WEB REPAIR BS 245, WL 227, UNDER CAPTAIN'S NR 3 WINDOW PER FED EX SRM 51-40-2.