What was found
DURING FLIGHT CONTROL CHECK, ELEVATOR WOULD ONLY MOVE HALFWAY FORWARD. HYDRAULIC PRESSURE WAS GOOD. FOUND RIGHT HAND STAB TRIM CONTROL ROD END ATTACH BOLT MIGRATED OUT, JAMMING POWER PACK. RESECURED BOLT. OPS CHECKS OKAY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING FLIGHT CONTROL CHECK, ELEVATOR WOULD ONLY MOVE HALFWAY FORWARD. HYDRAULIC PRESSURE WAS GOOD. FOUND RIGHT HAND STAB TRIM CONTROL ROD END ATTACH BOLT MIGRATED OUT, JAMMING POWER PACK. RESECURED BOLT. OPS CHECKS OKAY.