As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AT FLIGHT LEVEL OF 24,000 FEET AND DESCENDING A LEVEL 2 ALERT TANK 2 PUMPS OFF ILLUMINATED. THE FUEL SYSTEM CONTROLLER WAS IN AUTO AT THE TIME. SWITCHED THE SYSTEM TO MANUAL TO TRY TO TURN THE PUMPS ON AND AT THIS TIME THE NR 2 ENGINE FLAMED OUT. ACCOMPLISHED CHECKLISTS AND GOT A RESTART. REMOVED AND REPLACED THE NR 2 TANK FILL VALVE CONTROLLER. REMOVED AND REPLACED THE FUEL SYSTEM CONTROLLER. SYSTEM OPERATIONAL CHECK GOOD.