What was found
BULGE IN SKIN RT BS 383 FROM STR 19 TO STR 22, JUST FORWARD OF OXYGEN SERVICE. *S/D* FOUND TO BE OUT OF LIMITS PER FED-EX SRM 53-30-1. REMOVED SKIN PANEL BS 360 TO 441, STR 19 TO STR 26 RT AND FABRICATED REPLACEMENT SKIN PANEL, BS 360 TO BS 441 AND STR 19 TO STR 26 RT IAW FED-EX EA NR 7-5330-34962.