What was found
HEAVY EXFOLIATION CORROSION ON 360 FLOORBEAM AT LBL 4 TO RBL 2. CUTOUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-10-8 PG 18.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HEAVY EXFOLIATION CORROSION ON 360 FLOORBEAM AT LBL 4 TO RBL 2. CUTOUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-10-8 PG 18.