What was found
WHILE CONDUCTING THE PRESSURIZATION DISCREPANCY SHEET THE NR 1 STRUT OVERHEAT LIGHT BEGAN TO FLICKER. NR 1 BLEED OFF, LEFT PACK OFF, NR 2 BLEED CLOSED, NR 3 BLEED AND RIGHT PACK ON. RAN ALL 3 ENGINES, AND APU AND PACKS, UNABLE TO DUPLICATE. SYSTEM FUNCTIONAL CHECK OK PER MAINTENANCE MANUAL 26-14-0.