Service difficulty report · Clamp · Doug DC1010

Difficulty date
June 20, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N1841U
Make and model
Doug DC1010
Aircraft serial
46634
Engine
Ge CF66D
Part
Clamp
Part number
34H40600
Condition
Broken
Location
Nr 2 Engine
Stage of operation
NR
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF, NR 2 ENGINE PNEUMATIC MANIFOLD FAILURE LIGHT CAME ON. DURING TAKEOFF THE EGT ON NR 2 ENGINE WAS HIGH 925 WITH N1 REDUCED TO 100 PERCENT INDICATING A PNEUMATIC LEAK. *S/D* THE NUMBER 2 ENGINE BLEED DUCT CLAMP FAILED. THE DUCT BROKE LOOSE CAUSING THE MANIFOLD FAILURE LIGHT TO ILLUMINATE. REPLACED CLAMPS AND DUCT, REPAIRED DAMAGE TO SURROUNDING AREA.