RETURNED TO ORD DUE TO LOSS OF A-SYSTEM HYDRAULIC FLUID. A-SYSTEM PUMPS SHUT OFF 3 MINUTES AFTER HYDRAULIC FAILURE. *S/D* REPLACED FLAP INTERCONNECT VALVE AND ALL CASE RETURN FILTERS.